Industrial Waste Water Treatment
Page 4 / 4 |
|
|
|
|
|
Treatment
and
recycling of industrial waste water in an glass factory |
|
|
|
R.A.P.T.
reactor -
coagulation |
|
R.A.P.D.
reactor-
flocculation |
|
Final clarification
by dissolved air flottation :
HYDROFLOT |
|
|
|
Recycling of total treated flow is
possible for the
water supply of glass production machines. |
|
|
|
Treated water flow (for recycling or disposal to river) : 25 m³/h |
|
|
|
|
Biological aerobic treatment SBR
for industrial waste water in a industrial bakery |
|
|
|
Treatment capacity: |
|
Pollution = 430
kgCOD/j |
|
Disposal in a river |
|
|
|
Discharge limits : |
|
S.S.
< 60 mg/l |
|
B.O.D5 < 30 mg/l |
|
C.O.D
< 125 mg/l |
|
Total
Nitrogen < 20 mg/l |
|
|
|
Treatment
line : |
|
Two biological aerobic stages type « S.B.R. »
in line with flow
limiting device before disposal to the river |
|
|
|
Biological sludge thickening on
a drip table before agricultural disposal |
|
|
|
|
|
|
|
|
Physical-chimical
treatment for removal of non ferrous metal ions before disposal
outside the plant |
|
|
|
Treatment capacity: |
|
Flow = 40 m³/h |
|
|
|
Treatment line : |
|
|
|
R.A.P.T. reactor - coagulation |
|
R.A.P.D.
reactor
- floculation |
|
Decantation |
|
|
|
|
Biological treatment by activated sludges in brewing industry |
|
|
|
Neutralization / selector - biological treatment by activated sludges (fines bubbles insufflation) - phosphorus precipitation - sludge concentration - sludge storage |
|
|
|
Treatment capacity: |
|
Load = 770 kgDCO/j |
|
|
|
Tretament norms: |
|
BOD5= 25 mg/l |
|
COD= 200 mg/l |
|
Suspended solids= 60 mg/l |
|
Total nitrogent= 20 mg/l |
|
Total phosphorus= 5 mg/l |
|