Industrial Waste Water Treatment
Page 2 / 4 |
|
|
|
|
|
|
Aerobic biological treatment in a food
industry |
|
|
|
|
|
Technic used :
AERO-S(3)
coupled with an ALTERCYCL A/D |
|
|
|
|
|
Two alterned tanks :
aeration/settling |
|
|
|
|
|
Oxygen is supplied by three turbines
of 45kW each. |
|
|
|
|
|
Capacity of treatment : |
|
|
Flow = 1.200 m³/d |
|
|
Load = 1.500 kgCOD/d |
|
|
Rejection in surface water |
|
|
|
|
|
Discharge norms : |
|
|
Suspended solids : 50 mg/l |
|
|
BOD : 60 mg/l |
|
|
COD : 100 mg/l |
|
|
|
|
|
Dewatering of biological sludge |
|
|
|
Mechanical cloth filter |
|
|
|
|
|
Aerobic biological treatment in a dairy industry
|
|
|
|
|
|
Technic used :
AERO-P(2) followed by a
clarification tank. |
|
|
|
|
|
Capacity of treatment : |
|
|
Flow = 675 m³/d |
|
|
Load = 2.080 kgCOD/d |
|
|
|
|
|
Discharge norms : |
|
|
Suspended solids : 60 mg/l |
|
|
BOD : 30 mg/l |
|
|
COD : 120 mg/l |
|
|
|
|
|
Aeration is realised by
Immersed diffusers with fine bubbles. |
|
|